AXIAL FAN EBM A4E400AP02-12
-
Axial fan ebm A4E450AP01-01
-
AXIAL FAN EBM A4S250AH02-01
-
Axial fan Ebm A6E330-AA02-10
-
AXIAL FAN EBM ACi 4420 HH
-
AXIAL FAN EBM ACi 4420 HU
-
AXIAL FAN EBM ACi 4420 MLU
-
Axial fan Ebm S6E330AP02-34
-
Axial fan EBM W1G200-EC87-25 EBM-PAPST
-
Axial fan Ebm W1G200-EC91-44
-
Axial fan Ebm W2E250-CE65-01
-
Axial fan ebmpapst 4314R
-
Axial fan ebmpapst S4E350AN02-43
-
COMPACT FAN W2S130-BM03-01
-
EBM 8556N FAN - Ebm 8556N axial fan
-
EBM S4E315-AB06-07 fan
-
EBM S4E315-AC08-07 fan
-
EBM W1G200-EC91-45 fan
-
EBM W2E250-HQ52-12 fan
-
FAN EBM-PAPST AL90A31-2518LN122
-
S2D250 HELICAL FAN
-
HELICAL FAN W2E200-CI38-01
-
Radial fan Ebm 180 mm R2E180-CB28-01
-
Radial fan Ebm R2E190-RA26-57
-
Radial fan Ebm R2E190-RA26-58
-
Radial fan Ebm R2E220-AA40-05
-
Radial fan Ebm R2E225-RA92-09
-
Radial fan Ebm RG128/1300-3612
-
Radial fan Ebm RG148/1200-3633-0102003
-
Radial fan Ebm RL76/8600Z A60-3030LH-204
What is the difference between axial fan, centrifugal fan and tangential fan?
There are mainly three types of professional fans. These are the axial (or helical) fan on the one hand, the centrifugal (radial) fan on the other hand and the tangential fan. Their role is generally identical (allowing the cooling and distribution of a flow of cooled air in a space). However, their design differs and allows different uses which will better correspond to your needs depending on the case.
The principle of the axial fan is based on blades (hence its helical name) which rotate around an axis, generally driven by a motor. Air is drawn in at one end and discharged at the other, parallel to the axis. This means that the airflow is distributed evenly across the entire system area. This type of fan is said to produce cooled air of large volume at low pressure. This type of fan is often found in refrigerators where they circulate the cooled air. The larger the volume of the axial fan, the larger the ventilated surface area can be.
The centrifugal fan absorbs air but expels it through a 90° channel. These systems put the air under pressure like a funnel. The air comes out over a smaller surface than at the entrance but more forcefully. These systems are called low volume, high pressure. They are particularly used to cool targeted areas of a system more likely to rise in temperature or when air must be sent into ducts or pipes (for example in air conditioning).
The tangential fan has a specific shape and its air intake is wider than a conventional fan. It is very frequently found in air conditioners. They are low pressure.