175 Products
-
Tangential fan 60 mm left - QLK45
-
TANGENTIAL FAN 60x120mm
-
Tangential fan Ebm papst QLZ06/1800B46-2513-217
-
Tangential fan Ebm QL4 250 mm RIGHT
-
Tangential fan ebm QL4 300 mm RIGHT
-
TANGENTIAL FAN FERGAS 136809 28W
-
Tangential fan QL4 200 mm RIGHT
-
Tangential fan QL4 300 mm RIGHT
-
Tangential fan QLK45 120 mm Right
-
Tangential fan QLK45 120 mm Right 55442.25280 EBM-PAPST
-
Tangential fan QLK45 120 mm left
-
Tangential fan QLK45 180 mm right
-
TANGENTIAL FAN QLK45 180 mm right A185
-
Tangential fan QLK45 240 mm right
-
Tangential fan QLZ06 180 mm right
-
Tangential fan QLZ06 180 mm left
-
TANGENTIAL FAN QLZ06 300 mm
-
Tangential fan QLZ60 180 mm right
-
Tangential fan QLZ60 180 mm left
-
Tangential fan QLZ60 240 mm left
-
Teddington TF-MAG-4E-300A fan
-
Teddington TF-MAG-4E-330A fan
-
WELLINGTON ECR2/0571 fan
-
ZIEHL S0450 VD46 260W FAN
-
Fan ZIEHL-ABEGG FB045-4EK.4F.V4P
-
ZIEHL-ABEGG FAN FB045-VDK.4C.V4P
-
Fan ZIEHL-ABEGG FN050-4EK.4IV7P1 760W
-
FAN ZIEHL-ABEGG FN050-SDK.4FV7P1
-
ZIEHL-ABEGG FAN FN050-VDK.4I.V7
-
ZIEHL-ABEGG FAN FN063-SDK.4I.V7
-
YWF4E-420S
What is the difference between axial fan, centrifugal fan and tangential fan?
There are mainly three types of professional fans. These are the axial (or helical) fan on the one hand, the centrifugal (radial) fan on the other hand and the tangential fan. Their role is generally identical (allowing the cooling and distribution of a flow of cooled air in a space). However, their design differs and allows different uses which will better correspond to your needs depending on the case.
The principle of the axial fan is based on blades (hence its helical name) which rotate around an axis, generally driven by a motor. Air is drawn in at one end and discharged at the other, parallel to the axis. This means that the airflow is distributed evenly across the entire system area. This type of fan is said to produce cooled air of large volume at low pressure. This type of fan is often found in refrigerators where they circulate the cooled air. The larger the volume of the axial fan, the larger the ventilated surface area can be.
The centrifugal fan absorbs air but expels it through a 90° channel. These systems put the air under pressure like a funnel. The air comes out over a smaller surface than at the entrance but more forcefully. These systems are called low volume, high pressure. They are particularly used to cool targeted areas of a system more likely to rise in temperature or when air must be sent into ducts or pipes (for example in air conditioning).
The tangential fan has a specific shape and its air intake is wider than a conventional fan. It is very frequently found in air conditioners. They are low pressure.